Measurement Technique / In-Line Probes / Vortex In-Line Probes

Vortex Measuring Tube VA Di ... ZG1 – Standard

Attributes:
- measuring tube VA Di with inside diameter 25, 40, 50, 80 and 100 mm
- probe materials: stainless steel, Hastelloy, titanium
- working temperature range up to +180 °C
- sensor length 200 mm
- process connection with flange according to DIN2527 Form C
- suitable for fixed measuring of actual flow rate V/t [m³/h], flow velocity v [m/s] in clean as well as condensate and particulate-laden gases
- signal evalutaion with integrated or separate transducer UVA or system unit µP-Vortex
- an additional isolation / supply unit is necessary for ATEX applications category 1/2G and category 1/2D (zone 0, zone 20)
- Output signals:
- 4-20 mA (flow-proportional)
- quantity pulse / limit value
- configurable via RS232 interface and software UCOM (with integrated UVA)

technical data

 

Vortex Measuring Tube VA Di ... ZG1 Ex-d

Attributes:
- measuring tube VA Di with inside diameter 25, 40, 50, 80 and 100 mm and Exd explosion proof connection housing
- probe materials: stainless steel, Hastelloy, titanium and tantalum
- working temperature range up to +180 °C. Sensor length 200 mm. Process connection with flanges according to DIN2527 Form C
- suitable for fixed measuring of actual flow rate V/t [m³/h], flow velocity v [m/s] in clean as well as condensate and particulate-laden gases
- signal evalutaion with integrated or separate transducer UVA or system unit µP-Vortex
- for ATEX category 1G (zone 0) applications an additional isolation / supply unit LDX2 is necessary
- Output signals:
- 4-20 mA (flow-proportional)
- quantity pulse / limit value
- HART communication
- configurable via HART communication with HART modem adapter and PC software UCOM

technical data

 

Vortex Measuring Tube VA TP DN Exactflow II

Attributes:
- vortex measuring tube VA TP DN Exactflow - for test bench applications, for example when measuring engine intake air flow rate or filter flow rate. Measuring tube diameter 80, 100, 120, 140, 150, 175 und 200 mm
- transducer VTP-VA, integrated in the connection housing, for determining gas mass flow from actual flow rate, working pressure and working temperature
- tube connection via quick action tension rings
- Output signals:
2x analog outputs 4-20 mA: 1x 'short time constant', 1x 'precision', gas mass pulse or limit value (configurable), RS232
- configurable via RS232 interface with software UCOM and adapter
- accessories: connection pipe sections, flow rectifiers, quick action tension rings

technical data